Introduction to Functions
The integrated control system is built into the lifting point. The integrated control appliance and frequency conversion circuit are installed in the product equipment to realize constant speed drive in small volume, so as to realize the transformation of lifting point from functionality to numerical control. Because of the built-in control system, avoid multiple wiring in engineering transmission.
major function
·Provide RS-485, weak current dry contact input control;
·Real time monitoring of current, speed, distance and frequency is realized;
·Multi electron upper and lower limit positioning setting;
·The current weight limit function can be set;
·Up to 15 group codes and 9 bit codes can be used to realize the independent RS-485 address code of 135 devices;
·The detection algorithm of the system can realize the constant speed operation of the equipment during the lifting process of 0-rated weight, and the weight of both sides of the truss can be balanced and consistent during the lifting process.
·The supporting software can easily calculate the address code in hexadecimal